Thông tin sản phẩm
Portable Dry Block Temperature Calibrator
Model LR- Cal QUARTZ-35
Range -30 ° C. .. +150 ° C
The portable dry block temperature calibrator LR- Cal QUARTZ-35 serves as a resource and reference temperature in one unit, for testing and calibration of temperature measuring instruments of all kinds
- Temperature range -30 ... +150 ° C
- Ramp function
- Thermostat tests
- Computer aided calibration via RS232 interface
- Various block inserts with various holes for test available
- Retrofit "black body" for the calibration of non-contact infrared thermometers possible
Thông số kỹ thuật
Specification of the metal block Temperature Calibrator LR- Cal QUARTZ-35
Temperature range
|
-30 ° C. .. +150 ° C
|
Temperature display
|
Accuracy ± 0.15 ° C Resolution 0.01 ° / 0.1 ° (° C or ° F)
|
Stability of the controlled temperature
|
± 0.02 ° C at 0 ° C
|
Heating
|
max. 10 ° C per minute
|
Cooling
|
max. 5 ° C per minute
|
Temperature uniformity
|
at 150 ° C: radial ± 0.05 ° C (at 95 mm immersion depth) axial ± 0.05 ° C (at 85 mm immersion depth)
|
Block depth
|
150 mm (usable: 135 mm)
|
Block diameter
|
sleeves for use with 35 mm diameter
|
Power
|
230 VAC (115 VAC optional)
|
Power
|
300 VA
|
Interface
|
RS232
|
Housing Material
|
Metal
|
Weight
|
about 10 kg
|
Dimension
|
160 x 340 x 330 mm
|
Scope of delivery and accessories for the metal block temperature calibrator LR-Cal QUARTZ-35
Standard delivery:
- Portable metal block temperature calibrator LR- Cal QUARTZ-35 or QUARTZ-35-2I
- Spare fuses
- Cable for power supply
- Connection cable for thermostat tests
- 1 insert with 6 holes
(4 - 4.5 - 5.5 - 6.5 - 8.5 to 10.5 mm diameters
- Extraction tool for changing insert sleeves
- Manual
- Certificate of calibration (performance and accuracy)
- Execution only LR- Cal QUARTZ-35-2I:
Electrical connection cable (red / black), screw (red / black) for the two measurement inputs
Tùy chọn phụ kiện
Optional accessories:
Article number
|
Description
|
BB INSERT 01-QUARTZ
|
Retrofit kit with black radiator high emissivity, for calibration of non-contact infrared thermometers. Solid core, interior with graphite coating Incl. Precision reference sensor Pt 100 (4-wire)
|
REF-T-SENSOR PT
|
External precision reference sensor Pt 100 -100 ... +670 ° C, TC: 0.003850 1 / K; stability of <40 mK, diameter 6.35 mm, length 450 mm, protection tube made of Inconel connection to 4-wire circuit, including 2 m PTFE cable, insulated and tinned including case
|
DKD T-CAL-PT
|
DKD calibration to
|
RTAB T-CAL-PT
|
This constant calculation
|
RTAB2 T-CAL-PT
|
Alternatively, constant calculation including table of values (in degree increments)
|
507.0.999.0008.0
|
Insert sleeve without hole (to be drilled)
|
507.0.999.0010.0
|
Insert with 2 holes (6.5 to 19.5 mm dia.)
|
INS-SPEC 633-3
|
Insert with 1 .. 3 holes per customer (diameter 3.5 ... 20 mm)
|
INS-SPEC 633-6
|
Insert with 4 .. 6 holes per customer (diameter 3.5 ... 20 mm)
|
INS-SPEC 633-10
|
Insert with 7 .. 10 holes per customer (diameter 3.5 ... 20 mm)
|
TEMPKAL BAG
|
Carrying case with shoulder strap
|
TEMPKAL SUITCASE
|
Aluminium case
|
599.0.000.0003.0
|
PC software LR- Cal AQ2sp incl RS232 interface lead temperature sensor calibration: automatic calibration routine for all type of temperature sensor with advanced search features reference sensor stabilization, time-calibration data are stored for printing and Automatically Populated report. This procedure can therefore be run in manual mode to allow the operator to manually enter the data. . This is Particular useful When calibrating temperature device: such as digital thermometer or analogue thermo meter stress test: Simply set MAX and MIN value and the software will run on automatic stress test on single sensor or a batch. Advance thermostat calibration: Simply set the open and close temperature limits, type of thermostat, type of test and the software will Automatically run the test.
|